P/N: ETI0018-1215
DC/AC Power Inverter
1500 Watts
48 VDC In
100/110/120 VAC Out
Features
True sinewave output (THD < 3%)
Power On-Off Remote Control
Input & Output fully isolated
Load control cooling fan
Advanced microprocessor
Built-in transfer switch & AC circuit breaker
ROF (Remote Override Function) or ignition lockout function option
Speed up transfer time & synchronized operation with utility AC source
Input polarity reverse/ under voltage/ over voltage protections
Output short circuit/ overload/ over temperature protections
Tri-color indicators display input, output level & failure status
e-13/ CE /FCC approved
Model
Numbers:
ETI0018-1115
ETI0018-1015
ETI0018-1215
ETI0018-1615
ETI0018-1515
ETI0018-1715
AC
Output
AC
Voltage
100
/ 110 / 120 VAC
220
/ 230 / 240 VAC
Rated
Power
1500
W
Surge
Power
3000
W
Waveform
True
sinewave (THD < 3%)
Frequency
50
/ 60 Hz selectable by DIP switch
AC
Regulation
+/-
3%
Power
Factor Allowed
COS
-90° ~ COS +90°
Standard
Receptacles
HARDWARE
LED
Indicator
Input
voltage level, output load level & fault status
DC
Input
No
Load Current Draw
1.45A
0.75A
0.40A
1.40A
0.70A
0.40A
Stand-By
Current Draw
0.28A
0.15A
0.09A
0.28A
0.15A
0.09A
DC
Voltage
12
VDC
24
VDC
48
VDC
12
VDC
24
VDC
48
VDC
Voltage
Range
10.5~15.0
VDC
21~30
VDC
42~60
VDC
10.5~15.0
VDC
21~30
VDC
42~60
VDC
Efficiency
(Typ.)
88.0%
91.0%
92.0%
92.0%
93.0%
94.0%
Fuse
40A
x 5
20A
x 5
20A
x 3
40A
x 5
20A
x 5
20A
x 3
Circuit
Breaker
16
A
10
A
Synchronous
AC Transfer
Yes
Transfer
Switch
25
A
Transfer
Time
Inverter
to utility AC:8~10 msec.: Utility AC to inverter:12~14
msec
Remote
Control Unit
CR6
/ CR8
optional
Protection
Low
Battery Alarm
11
VDC
22
VDC
44
VDC
11
VDC
22
VDC
44
VDC
Low
Battery Shutdown
10.5
VDC
21.0
VDC
42.0
VDC
10.5
VDC
21.0
VDC
42.0
VDC
Over
load
Shut
off output voltage, re-power on to recover
Over
Voltage
15.3
VDC
30.6
VDC
61.2
VDC
15.3
VDC
30.6
VDC
61.2
VDC
Over
Temperature
Shut
off output voltage, recovers automatically after temperature
goes down