Model
Numbers:
|
ETI0018-1125
|
ETI0018-1025
|
ETI0018-1225
|
ETI0018-1625
|
ETI0018-1525
|
ETI0018-1725
|
|
AC
Output |
AC
Voltage
|
100
/ 110 / 120 VAC |
220
/ 230 / 240 VAC |
Rated
Power
|
2500
W |
Surge
Power
|
5000
W |
Waveform
|
True
sinewave (THD < 3%) |
Frequency
|
50
/ 60 Hz selectable by DIP switch |
AC
Regulation
|
+/-
3% |
Power
Factor Allowed
|
COS
-90° ~ COS +90° |
Standard
Receptacles
|
HARDWARE |
LED
Indicator
|
Input
voltage level, output load level & fault status |
DC
Input
|
No
Load Current Draw
|
2.62A |
1.53A |
0.72A |
2.32A |
1.15A |
0.68A |
Stand-By
Current Draw
|
0.60A |
0.30A |
0.20A |
0.60A |
0.30A |
0.15A |
DC
Voltage
|
12
VDC |
24
VDC |
48
VDC |
12
VDC |
24
VDC |
48
VDC |
Voltage
Range
|
10.5~15.0
VDC |
21~30
VDC |
42~60
VDC |
10.5~15.0
VDC |
21~30
VDC |
42~60
VDC |
Efficiency
(Typ.)
|
88.0% |
91.0% |
92.0% |
90.0% |
93.0% |
94.0% |
Fuse
|
40A
x 10 |
20A
x 10 |
20A
x 6 |
40A
x 10 |
20A
x 10 |
20A
x 6 |
Circuit
Breaker
|
35
A |
15
A |
Synchronous
AC Transfer
|
Yes |
Transfer
Switch
|
25
A |
15
A |
Transfer
Time
|
Inverter
to utility AC:8~10 msec.: Utility AC to inverter:12~14
msec |
Remote
Control Unit
|
CR6
/ CR8
optional |
Protection
|
Low
Battery Alarm
|
11
VDC |
22
VDC |
44
VDC |
11
VDC |
22
VDC |
44
VDC |
Low
Battery Shutdown
|
10.5
VDC |
21.0
VDC |
42.0
VDC |
10.5
VDC |
21.0
VDC |
42.0
VDC |
Over
load
|
Shut
off output voltage, re-power on to recover |
Over
Voltage
|
15.3
VDC |
30.6
VDC |
61.2
VDC |
15.3
VDC |
30.6
VDC |
61.2
VDC |
Over
Temperature
|
Shut
off output voltage, recovers automatically after temperature
goes down |
Output
Short
|
Shut
off output voltage, re-power on to recover |
Battery
Polarity
|
By
fuse opening |
Environmental
|
Working
Temperature
|
0
~ +40° C |
Working
Humidity
|
20%
~ 90% RH non-condensing |
Storage
Temp. Humidity
|
-30° C
~ +70° C / -22° F ~ +158° F / 10~95% |
Standards
|
Safety
Standards
|
Meets
UL458 |
|
Isolation
Resistance
|
I/P
~ O/P: 100M Ohms / 500 VDC |
EMI & Radiation
|
Compliance
to FCC Class A |
Compliance
to EN55022 Class A |
EMS
Immunity
|
|
Compliance
to EN61000-3 -2, 3 |
LVD
|
Compliance
to EN60950-1 |
e-MARK
|
Compliance
to e-13 * 72/245/EEC, 95/54/EC |
Mechanical
|
Dimensions
|
463
x 332 x 115 MM (L x W x H) |
Packaging
|
12
kgs; 1 set / 13 kgs / CARTON |
Cooling
|
Load
controlled cooling fan |
|
This
page was last modified on: May 17, 2008
|
 |
 |
 |
|
|
Copyright © 2000-2008 Energy Technologies, Inc.- All Worldwide
Rights Reserved.
TacticalPower®, Tactical Fuel Cells®, Tactical Generator®, Tactical Inverter®, TacticalPowerPlant®, Tactical Solar® and Military Power® are registered
trademarks of Energy Technologies, Inc.
TacticalBriefcase™, TacticalCables™, TacticalComputers™, and
TacticalECU™
are trademarks of Energy Technologies, Inc. Send comments or questions
regarding this site to: webmaster@tacticalpower.com
|