The field proven WorldPower UPS line is ideally suited for
military, industrial, computer and telecommunications applications
requiring high reliability, rugged construction, compact
size and light weight design. These units are equally suited
for use in shipboard, airborne, vehicular, field deployed
or fixed locations with controlled or uncontrolled environments.
The ETI0001-1251 is specifically designed for lightweight
global power deployment or equally well in shallow depth
racks including TAC-4 racks and interfacing with any of
numerous ETI PDUs.
The
heavy-duty chassis occupies only 7" (4U) of rack space
while delivering up to 1550 VA of clean, uninterruptible
power. The rounded metal corners and rugged handles, aid
in safe handling. Internally, all major components are
well secured and electrically insulated to prevent damage
due to shock and vibration. The optional heavy-duty rack
slides provide easy installation and removal of the unit
with full extension.
The
internal shielded input transformer provides galvanic isolation
with provisions for both domestic (115 VAC, CONUS) and
international (230 VAC, OCONUS) input voltages. The autoranging
input voltage selection allows inputting either 115 VAC
or 230 VAC without having to open the UPS enclosure. Special
EMI/RFI filters and input power factor correction minimize
both input current and harmonics. The input switch and
the galvanic isolation transformer provide a double
pole isolated source for shipboard systems or overseas
locations where phase references and grounding are not
consistent. Alternately,
the unit also accepts vehicular or aircraft power from
nominal 24 VDC systems. This allows the unit to be
operated when no AC source is available.
The
LED arrays keep the operator informed as to the unit's
status including load and battery levels. The high intensity
audible alarm can be heard in high noise environments.
All controls and protective devices are brought to front
and rear panels with critical switches having finger guards.
Further, all front panel devices are recessed to prevent
damage or accidental operation.
The
rear panel provides locking connectors for the input and
output power with various optional configurations available.
This reverse air flow version draws air through the front
and exhausts out the rear vent into the rack. A removable
and washable intake air filter and high capacity stainless
steel ball bearing fan provide added protection in both
controlled and hostile environments. The batteries are
maintenance free with immobilized electrolyte and are constructed
of flame retardant materials. For more information, see
the Battery Technology section.
The two status D shell connectors provide both a contact
and serial interface with optional computer
software providing loss of AC and low battery status
as well as remote shut down capability.
Overall,
the WorldPower line is uniquely qualified for critical
shipboard, vehicle, airborne or land based systems combining
advanced modular design features with highly reliable construction.
Technical
Specifications: ETI0001-1251
| AC OUTPUT |
| Output
voltage: |
120
VAC true sinewave std, up to 600 VAC optional |
| Output
rating: UPS |
1550
VA, standard in 4U x 19" chassis
0.65-0.75 pf std, optional configurations to 24,000 VA |
| Non-linear
load capacity: |
Up
to 100% non-linear load capability w/o derating |
| Output
voltage regulation: UPS |
± 3.0%
static regulation of nominal
± 4.0% dynamic (0 to 50% load step) |
| Overload
surge capacity: |
110%
for 10 minutes; 125% for 30 seconds |
| Harmonic
distortion: |
Less
than 5.0% into 100% non-linear load |
| Output
frequency: UPS |
60
Hz ± 1.0% independent of input frequency |
| Operational
status |
Status,
load and battery (16) LEDs, w/contacts
RS-232 asynchronous serial status COM port
Adjustable level,+90 dB audible alarm w/on/off |
| AC INPUT |
| Input
voltage selection: |
Autoranging
from nominal 115 VAC to 230 VAC |
| Input
voltage tolerance: UPS |
+15%
-25%, or 85-135 and 170-270 |
| Input
frequency: |
From
46 Hz to 440 Hz |
| Input
power factor: |
Better
than 99% typically |
| Input/output
isolation: |
2000
VA, >120 dB common mode, <1.0 ma leakage |
| Input
transient suppression: |
Complies
with IEEE 587 and UL 1449 |
| Input
control/protection: |
Guarded
2 pole switch (S1) w/fuse (F2) |
| Input
power connection: |
MS
3102A-22-2P, 3 pin, locking |
| DC
INPUT / INTERNAL BATTERY |
| External
DC input: |
Nominal
22 to 32 VDC |
| External
DC control/protection: |
Guarded
2 pole switch (S3) w/rear mounted fuse (F3) |
| External
DC connector: |
MS
3102A-24-9P, 2 pin, locking |
| Internal
battery type: |
Maintenance
free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+) |
| Internal
battery life: |
Rated
for continuous service life of 5 years |
| Internal
battery protection: |
Rear
panel mounted fuse (F1) |
| Internal
battery time: |
10+
minutes @ 1000 watt load, 20+ minutes @ 50% |
| Internal
battery recharge: |
Recharged
to nominal in <8 hours |
| Internal
battery replacement: |
Drawout/plug-in
module from front of unit |
| DISTRIBUTION PANEL |
| Output
circuits: |
Six
outputs standard, optional configurations |
| Output
control: |
Guarded
3 pole switch (S5) |
| Output
receptacles: |
Metal
shell NEMA 5-15R, 3 pin locking, other options |
| MECHANICAL |
| Dimensions
( H x D x W ): |
7.00
(4U) x19.0 x 19.0 in (178 x 483 x 483 mm) |
| Rack
Slide Mount Patterns: |
Jonathan,
General Devices, others optional |
| Alternate
Mounting Options: |
Table,
Wall, Floor, Portable, Horizontal/Vertical |
| Unit
weight: |
98
lb. (45 kg) with lift handles front and rear |
| Audible
noise: |
Less
than 47 dB @ 5.0 ft., ANSI "A" scale |
| Cooling
type: |
High
capacity, negative pressure, forced air |
| Cooling
air direction: |
Front
intake, exhaust to rear |
| Air
intake filter: |
Washable
metal filter media, others optional |
| ENVIRONMENTAL |
| Storage
temperature: |
-13° to
140° F ambient (-25° to 60° C) |
| Operating
temperature: |
50° to
104° F ambient ( 10° to 40° C) |
| Operating
humidity: |
0
to 95% relative humidity (non-condensing) |
| Storage
elevation: |
Up
to 40,000 ft (12,192 m), higher optionally |
| Operating
elevation: |
Up
to 10,000 ft (3,048 m), higher optionally |
| STANDARDS |
| United
States: |
Meets
UL-1778 standard for UPS equipment,
Meets MIL-STDs 1275, 167-1, 454, 810, 1399-300A &
MIL-S-901 |
| Canada: |
CSA
C22.2 No. 107 UPS safety requirements |
| EMI
Protection: |
EMI/RFI
FCC, Class A; EN55022; MIL STD 461 |
| OPTIONAL ACCESSORIES |
| |
Emergency Power Off, Elapsed Time
Meter, Cold Start, Alternate I/O Configurations, Dual