ETI018-1210 DC/AC Power Inverter 1500 VA, 1000 Watts 48 VDC In

P/N: ETI0018-1210
DC/AC Power Inverter
1500 VA, 1000 Watts
48 VDC In


Selectable 100/110/120* VAC Out

Features:

True sinewave output (THD < 3%)
Power On-Off Remote Control
Input & Output fully isolated
Load control cooling fan
Advanced microprocessor
Output frequency 50/60 Hz switch selectable
Low power saving mode to conserve energy
Built-in transfer switch & AC circuit breaker
ROF (Remote Override Function) or ignition lockout function option
Speed up transfer time & synchronized operation with utility AC source
Input polarity reverse/ under voltage/ over voltage protections
Output short circuit/ overload/ over temperature protections
Tri-color indicators display input, output level & failure status
e-13/ CE /FCC approved
Optional 220 /230 /240 VAC Out

Rugged Universal Mount Sinewave Inverter

rear view of universal mount inverter

Model Numbers:
AC Output
AC Voltage
100 / 110 / 120 VAC
Rated Power
1000 W
Surge Power
2000 W
Waveform
True sinewave (THD < 3%)
Frequency
50 / 60 Hz selectable by DIP switch
AC Regulation
+/- 3%
Power Factor Allowed
COS -90° ~ COS +90°
Standard Receptacles
HARDWARE
LED Indicator
Input voltage level, output load level & fault status
DC Input
No Load Current Draw
 1.43A  0.75A  0.38A
Stand-By Current Draw
 0.25A  0.15A  0.09A
DC Voltage
 12 VDC   24 VDC  48 VDC
Voltage Range
 10.5~15.0 VDC  21~30 VDC  42~60 VDC
Efficiency (Typ.)
 88.0%  91.0%  92.0%
Fuse
 40A x 4  20A x 4  20A x 2
Circuit Breaker
12 A
Synchronous AC Transfer
Yes
Transfer Switch
16
Transfer Time
Inverter to utility AC:8~10 msec.; Utility AC to inverter: 12~14 msec
Remote Control Unit
CR6 / CR8 optional
Protection
Low Battery Alarm
 11 VDC  22 VDC  44 VDC
Low Battery Shutdown
 10.5 VDC  21.0 VDC  42.0 VDC
Over load
Shut off output voltage, re-power on to recover
Over Voltage
 15.3 VDC  30.6 VDC  61.2 VDC
Over Temperature
Shut off output voltage, recovers automatically after temperature goes down 
Output Short
Shut off output voltage, re-power on to recover
Battery Polarity
By fuse opening
Environmental
Working Temperature
0 ~ +40° C
Working Humidity
20% ~ 90% RH non-condensing
Storage Temp. Humidity
-30° C ~ +70° C / -22° F ~ +158° F / 10~95%
Standards
Safety Standards
Meets UL458
Isolation Resistance
I/P ~ O/P: 100M Ohms / 500 VDC
EMI & Radiation
Compliance to FCC Class A
EMS Immunity
LVD
e-MARK
Mechanical
Dimensions
373 x 236 x 115 MM (L x W x H)
Packaging
6.2 kgs; 2 sets / 14 kgs / CARTON
Cooling
Load controlled cooling fan

Request a Quote or Product Info.
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466