P/N: ETI0018-2103
Tactical Briefcase DC/AC Power Inverter
500 VA, 350 Watts
12 VDC In, 120 VAC Out
This field-proven Series of Tactical Inverter® is supplied as a System incorporating numerous safety and operational advantages over other Inverter products sold into this market. The Inverter and associated connectors, circuit breakers and cables are housed in a rugged, water-resistant, tactical case. When the case is closed, all of the equipment is protected from the elements. Optional permanent mounting bracket are available for fixed installations.
Setup of the Tactical Inverter System is a 'no tools' operation. The unit has been designed for rapid setup and tear down using quick-connect cable terminations. For example to connect to DC power on an HMMWV, Stryker, Abrams or other military vehicle with a NATO Slave connector, simply open the cover of the system case, plug the NATO Slave plug end of the cable into the vehicle's NATO connector and then plug the other end into the corresponding DC Input connector on the Tactical Inverter System. This can be done with an existing NATO Slave cable that some of these vehicle carry; or it can be done with a cable supplied from ETI. In either case, DC setup or tear down is a 2-minute or less operation.
The Inverter draws power from a 12, 24, or 48 VDC source (depending on Tactical Inverter model - see Technical Specifications section) and delivers a Computer-Grade true sine wave AC output voltage that is equal to or better than the voltage supplied by your local utility. When the DC voltage is within the operating range of the unit, the Inverter will continue to deliver AC power to the loads connected. If the DC voltage falls out of the specified range of operation, a Low or High DC Shutdown will occur respectively. This feature also protects any battery source from being discharged too low.
AC OUTPUT | |
Output voltage: | 120 VAC
true sinewave Optional 220 VAC |
Output rating: | 1000 VA, 700 watts continuous |
Output voltage regulation: | ± 3.0%
static regulation of nominal -10% to +4.0% dynamic |
Overload surge capacity: | 1200 watts surge for 5 seconds |
Output protection: | Overcurrent protection |
Harmonic distortion: | Less than 3.0% THD |
Output frequency: | 60 Hz ± 0.5% crystal
controlled Optional 50 Hz |
Operational status | LEDs and audible alarm |
DC INPUT | |
Input voltage selection: | Nominal 12 VDC |
Input voltage tolerance: | 10.5-15 VDC |
Input control/protection: | 2-pole
Guarded DC Circuit Breaker, Under/Over voltage, Input Reverse Protection, Low Voltage Disconnect (LVD) protecting source so vehicle battery does not go below starting voltage |
Input power connection: | Quick connect (1) NATO Slave female and Quick connect (1) Anderson Power Pole |
Input power cable: | Uses standard NATO Slave male-male cable or Optional 10' Anderson to NATO Slave male connector |
DISTRIBUTION PANEL | |
Output circuits: | Four outputs standard |
Output protection: | GFCI, Ground Fault Circuit Interrupter |
Output control: | Optional panel switches or breakers Optional remote interlock ON/OFF control |
Output receptacles: | NEMA 5-15R straight blade standard |
Ground connection: | Quick connect jack |
MECHANICAL | |
Enclosure type: | Mil Grade Briefcase, water tight to -30 ft w/pressure relief valve, lockable |
Dimensions ( H x D x W ): | 6.1 in (155 mm) x 12.2 in (310 mm) x 17.2 in (437 mm) |
Unit weight: | 20 lb. (9 kg) with rugged, folding lift handle |
Audible noise: | <47 dBA @ 5 ft., ANSI "A" scale |
Cooling type: | Positive pressure fan.
thermostatically controlled, over temperature protection |
Air intake filter: | Easy clean intake air filter |
ENVIRONMENTAL | |
Storage temperature: | -40° to
160° F ambient (-40° to 71° C), lower/higher optional |
Operating temperature: | -25° to 140° F ambient (-32° to 60° C ) lower/higher optional |
Operating humidity: | 0 to 95%
relative humidity, non-condensing, higher optional |
Storage elevation: | Up to 40,000 ft (12,192 m) |
Operating elevation: | Up to 10,000 ft (3,048 m), higher optional |
STANDARDS | |
United States: | Meets UL-1741 and 458 |
Canada: | Meets CSA 107.1 safety requirements |
International: | Meets EN60950-1 safety requirements |
Electromagnetic Compliance (EMC): |
EMI/RFI
FCC Part 15, Class B, EN55022:1997, EN61000-3-2:1998, EN61000-3-3:1995, EN550204:2001, e-Mark e13-022025, Others optional |
OPTIONAL ACCESSORIES | |
Input Cables, Ground Cables w/ Clamp, Ground Rod Kit, Power Distribution Units, Remote Control/Monitor Panel |